REFERENCE TABLE · CONSTRUCTION · PVC

PVC Pipe Size Chart: Schedule 40 & 80

Every common PVC pipe size from 1/2″ to 4″ with the published ASTM D1785 numbers: outside diameter, wall thickness, inside diameter, and weight per foot — for Schedule 40 and Schedule 80 side by side. Pick a size and length above and the calculator returns the full spec plus total weight: 2″ Schedule 40 × 10 ft = 7.20 lb. The full printable chart is under the calculator.

465

PVC pipe lookup

Pick a nominal size, a schedule, and the total length in feet. The calculator returns the pipe’s published specs — outside diameter, inside diameter, wall thickness, and weight per foot — plus the total weight. Values come straight from the ASTM D1785 standard table.

Nominal size is not the actual diameter — a “2-inch pipe” has a 2.375″ OD. The OD is identical for both schedules; the schedule changes the wall.

Schedule 40 is the standard for drain/waste/vent and cold-water supply. Schedule 80 has a thicker wall for pressure service, exposed mechanical work, and high-pressure pump lines.

The combined length of all pieces of this size and schedule. Pipe is usually sold in 10-ft and 20-ft sticks — enter 20 for one full stick.

Result—Enter values above

Enter values to see the result.

The 60-second rule

Nominal ≠ actual; schedule = wall. A “2-inch pipe” has a 2.375″ outside diameter — the nominal size is a name, not a measurement. The OD never changes between schedules; Schedule 80 just adds wall thickness, which shrinks the inside (2″ Sch 40: 2.067″ ID; 2″ Sch 80: 1.939″ ID) and adds weight (0.720 vs 0.95 lb/ft). Default check: 2″ Sch 40 × 10 ft = 0.720 × 10 = 7.20 lb. ID on this page is always the calculated ID — OD minus twice the wall, applied to every row; some published tables print a slightly different “average ID,” which is why numbers vary a few hundredths between charts. Use Schedule 40 for drainage and cold water; step up to 80 when the pipe carries real pressure or lives exposed. And always build to your local plumbing code, not to this chart alone.

The worked example, line by line

Setup: 2″ Schedule 40 PVC and 10 feet of it.

Line 1 — the specs. From the ASTM D1785 table: OD 2.375″, wall 0.154″, ID 2.067″, weight 0.720 lb/ft. The ID is OD minus twice the wall — 2.375 − 2 × 0.154 = 2.067 — the calculated-ID convention this page uses on every row, so you can verify any cell yourself.

Line 2 — the total. 0.720 lb/ft × 10 ft = 7.20 lb — one 10-ft stick you can carry under one arm.

Branch — pressure service (1″ Sch 80 × 25 ft): thicker wall 0.179″, ID 0.957″, 0.41 lb/ft × 25 ft = 10.25 lb — typical for a well-pump drop line.

Branch — a sewer main (3″ Sch 40 × 10 ft): OD 3.500″, ID 3.068″, 1.488 lb/ft × 10 ft = 14.88 lb — the drain-waste-vent workhorse.

Branch — a full irrigation run (1/2″ Sch 80 × 100 ft): 0.20 lb/ft × 100 ft = 20.00 lb — the thicker wall earns its keep where a lawnmower or a shovel might find the pipe.

The full standard chart

NominalOD (in)Schedule 40 — wall / ID / lb-ftSchedule 80 — wall / ID / lb-ftTypical use
1/2″0.8400.1090.6220.1700.1470.5460.20Irrigation laterals, pool returns, drip lines
3/4″1.0500.1130.8240.2260.1540.7420.27Sprinkler heads, pool equipment, cold-water branches
1″1.3150.1331.0490.3330.1790.9570.41Main water service lines, well drop pipe
1-1/4″1.6600.1401.3800.4500.1911.2780.52Pump discharge lines, well pump columns
1-1/2″1.9000.1451.6100.5370.2001.5000.67Drain branches, pump suction lines
2″2.3750.1542.0670.7200.2181.9390.95Building drains, pool circulation mains
2-1/2″2.8750.2032.4691.1360.2762.3231.45Commercial drain stacks
3″3.5000.2163.0681.4880.3002.9001.94Sewer mains, DWV stacks
4″4.5000.2374.0262.1180.3373.8262.75Building sewers, main drains

Output · formula · meaning

OutputFormulaWhat it means
Total weight (lb)weight per foot × length7.20 lb at the defaults — the number your supplier bills by.
Outside diameterfrom the standard table2.375 in for 2″ — the dimension fittings are made to; identical for both schedules.
Inside diameterfrom the standard table2.067 in for 2″ Sch 40 — the bore the water actually sees; shrinks to 1.939 in Sch 80.
Wall thicknessfrom the standard table0.154 in for 2″ Sch 40 — the schedule’s whole identity.
Typical useindustry conventionBuilding drains, pool circulation mains for 2″ — a starting point, not a code ruling.

Who uses this

  • The weekend irrigator laying 100 ft of 1/2″ Sch 80: looks up 0.20 lb/ft, multiplies to 20.00 lb, and buys exactly two 10-ft-stick bundles’ worth with no guesswork.
  • The pool contractor swapping a circulation main: confirms the 2″ Sch 40 bore is 2.067″ — not the 1.939″ of Sch 80 — because flow rate cares about the inside, not the label.
  • The well driller pricing a drop line: runs 1″ Sch 80 × 25 ft = 10.25 lb and specs the thicker wall where the pump’s pressure spikes live.
  • The home inspector checking a sewer main: verifies the 4″ pipe on site matches a 4.500″ OD — and that the “3-inch” the contractor mentioned is really 3.500″ outside.

Accuracy & limitations

All ODs, walls, and weights are the ASTM D1785 published nominal values — nominal wall is a minimum, so real pipe can run slightly thicker (and heavier) within tolerance. IDs are the calculated ID (OD − 2 × wall), applied consistently; some tables print an “average ID” that reads a few hundredths smaller, which is the usual reason two charts disagree. Weights are for the pipe body only — fittings, glue, and hangers aren’t included. This page covers PVC Schedule 40 and 80, 1/2″ through 4″ only — it does not cover CPVC, ABS, SDR-series pipe, or pressure ratings (PVC derates above 73°F and is not for hot water). Typical-use column is industry convention. Pipe selection is code work: always build to your local plumbing code and your engineer’s spec.

Cite this calculatorBright Side Kit. “PVC Pipe Chart: Schedule 40 & 80 Specs | Bright Side Kit.” brightoolbox.com, 2026.Bright Side Kit. "PVC Pipe Chart: Schedule 40 & 80 Specs | Bright Side Kit." https://brightoolbox.com/pvc-pipe-size-chart/ Accessed October 24, 2026.Data sources
  • ASTM D1785 — Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80, and 120 (nominal dimensions and weights).
  • Schedule 40 values cross-checked against two published tables agreeing to three decimals (Zoro industrial guide; PlasticRanger pipe guide).
  • Schedule 80 values cross-checked against Ficient Design’s engineering dimension tables and a published PVC/CPVC pipe chart (wall, ID, and weight columns).
  • Wall thicknesses additionally cross-checked across three published tables (Metal Supermarkets pipe schedule chart; a Schedule 40 vs 80 comparison chart) — all agree to the thousandth.
  • Typical-use guidance follows industry convention (irrigation 1/2″, service lines 1″, DWV 2–4″) — always confirm with local code.
Embed this calculator

Paste this into any web page to embed the live calculator. The “Bright Side Kit” link below it must stay intact.

Frequently asked questions

What does Schedule 40 vs Schedule 80 mean?

“Schedule” is the wall-thickness family. For the same nominal size, Schedule 80 has a thicker wall (2″: 0.218″ vs 0.154″), a smaller inside diameter (1.939″ vs 2.047″), and more weight per foot (0.95 vs 0.720 lb/ft) — while the outside diameter is identical (2.375″), so both use the same fittings. Use 40 for drainage and cold water; use 80 for pressure and exposed work. And don’t judge by color: color does not tell you the schedule — white, gray, and even blue pipe are all made in both schedules. Read the print on the pipe wall.

Is a 2-inch PVC pipe actually 2 inches?

No. Nominal size is a name, not a measurement — a “2-inch” pipe has a 2.375″ outside diameter and a 2.047″ inside diameter (Schedule 40). The same naming applies across the chart: “1-inch” is really 1.315″ OD. Always look up the real numbers before drilling holes or sizing pumps.

What size PVC pipe do I need for a sprinkler system?

Most residential zones run 3/4″ or 1″ — 3/4″ for the laterals feeding the heads, 1″ for the main line from the valve box. Drip and micro-spray laterals often drop to 1/2″. Size by flow and pressure loss, not by habit — and check your local code for backflow-prevention rules before you dig.

Can Schedule 40 PVC be used for hot water?

No. PVC is rated to 140°F maximum, and its pressure rating derates as temperature rises — it is a cold-water and drain material. For hot-water distribution, CPVC (rated to ~200°F) or another code-approved material is the standard choice.

What size PVC pipe for a main drain or sewer line?

Residential building drains and sewers are typically 3″ or 4″ Schedule 40 — 4″ (4.500″ OD, 3.998″ ID) is the common building-sewer size. Minimum sizes, slopes, and cleanout spacing are code items, not chart items: confirm with your local plumbing code before trenching.

Why does 1-inch PVC measure 1.315 inches?

Because nominal size is a legacy name, not a measurement — it dates to early pipe dimensions and the name stuck while the standards moved on. A “1-inch” PVC pipe has a 1.315″ outside diameter and a 1.049″ inside diameter (Schedule 40). Drill holes, size pumps, and buy fittings by the OD, never by the name on the shelf tag.

Is PVC measured inside or outside?

Both — for different jobs. Fittings, OD-based tools, and hole saws work off the outside diameter (which is identical for Schedule 40 and 80, so fittings are interchangeable between schedules). Flow calculations work off the inside diameter. One more trap: this chart is IPS (iron pipe size); CTS (copper tube size) pipe used for indoor supply lines has smaller ODs at the same nominal size — never mix the two systems on one run.

How much does a 10-foot stick of 2-inch PVC weigh?

7.20 lb: 0.720 lb/ft × 10 ft (2″ Schedule 40). The same stick in Schedule 80 weighs 9.50 lb (0.95 lb/ft) — the thicker wall’s price, in pounds.